30' x 40' · 1,200 sq ft footprint

30x40 Barndominium Floor Plans in Georgia

30 feet by 40 feet is 1,200 sq ft under roof. In most of the country that is simply a small house. In Georgia it is a number you have to check against the county first, because minimum heated floor area is set locally and the spread is enormous: Forsyth County requires 700 sq ft per dwelling unit, Coweta County requires 1,725. A 30x40 built as 1,200 sq ft of living space is comfortably legal in Forsyth and Cherokee, lands exactly on Bartow County's 1,200 sq ft line with nothing to spare, and falls short in Walton, Jackson and Coweta. The 30-foot direction is the clear span and the 40-foot direction is the cheap one, so where the footprint does need to grow, length is the inexpensive way to get it.

What actually changes at this size

The dimensions are the easy part. These are the decisions that follow from them.

The minimum floor area spread

Forsyth County 700 sq ft per dwelling unit in A1 and AG-Res. Newton County 1,000 sq ft in A but 1,800 in RE and AR. Paulding County 1,100 sq ft in A-1 but 1,600 in R-1. Bartow County 1,200. Walton County and Jackson County 1,400. Coweta County 1,725. South Fulton 1,800 on the ground floor for a single-storey house. Note the inversions in Newton and Paulding: the district with the larger minimum lot has the smaller minimum house.

Shop space does not count toward it

Where a Georgia county sets a minimum, it is almost always stated on heated floor area. Jackson County's UDC § 105 spells out that heated floor area excludes garages, unheated basements, attic storage and partially enclosed decks. So splitting a 30x40 into 800 sq ft of living space and a 400 sq ft shop bay does not just shrink the house, it shrinks the number the county measures — and drops the building below minimums that the full 1,200 sq ft would have cleared.

Clear span orientation

The 30-foot dimension is built as the clear span. The 40-foot dimension is simply the direction posts, frames or trusses are spaced out along, which makes it the cheap direction to grow. If the plan needs more square footage, 30x50 or 30x60 costs less than 40x40 for the same added area, because widening the span steps the frame up faster than the floor area rises.

What fits in 1,200 sq ft

One bedroom with real breathing room, two bedrooms and two baths as the comfortable default, or three bedrooms with modest room sizes. Thirty feet of width is enough to run bedrooms down one side and living space down the other rather than a single corridor with rooms off it, which is what makes this footprint work better than the area alone suggests. On a rural parcel the bedroom count also drives the septic design, so a third bedroom added purely for resale has a cost beyond the framing.

Check the county before the plan

1,200 sq ft is below the minimum house size in Walton, Jackson and Coweta counties

Coweta County sets a minimum floor area of 1,725 sq ft per dwelling unit in its Rural Conservation district. Walton County requires 1,400 sq ft in its A and A1 districts. Jackson County requires 1,400 sq ft of heated gross floor area for a barndominium specifically, under UDC § 3-050(b). Bartow County's minimum is 1,200 sq ft of heated living space, which a nominal 30x40 meets only if the county measures the way you drew it. Forsyth County requires 700 sq ft and Cherokee County publishes no minimum for a site-built dwelling at all. Same building, six different answers. We confirm the minimum floor area for your county and zoning district before anything gets drawn.

How people actually split 1,200 sq ft

Common configurations we see at this footprint. Yours does not have to match one exactly — this is a starting point for the conversation, not a catalog.

Two bedrooms, two baths, all living space

1,200 sq ft living / no shop

The default at this footprint and the one most 30x40 plans resolve to. A primary bedroom and a second bedroom or office, two baths, open kitchen and living across the 30-foot width. Clears the minimum in Forsyth, Cherokee, Fannin, Newton's A district and Paulding's A-1, and lands on the line in Bartow.

One bedroom, open plan

1,200 sq ft living / no shop

One bedroom and one or two baths, with the space that would have been a second bedroom given back to the kitchen and living area. The usual shape for a couple, a downsizer, a weekend place in the North Georgia mountains, or a rental. Worth checking the ceiling rather than the floor here: Hall County caps an accessory dwelling unit at 1,000 sq ft, so 1,200 is too large to be an ADU there.

Ground floor plus loft

1,200 sq ft ground floor / 300 to 400 sq ft loft

Adds sleeping or office space without widening the frame or lengthening the building. This is also the one route South Fulton names directly: its AG-1 standard asks for 1,800 sq ft on the ground floor for a single-storey house, but only 1,200 sq ft on the ground floor if the house is two storeys and 2,000 sq ft in total — and a 30x40 footprint satisfies that ground-floor test.

Stretched down the cheap axis for a shop

1,200 sq ft living / 300 to 600 sq ft shop, on a 30x50 or 30x60

The honest way to put a shop on this plan. Adding bays along the 40-foot axis keeps the living area intact and keeps the frame at its efficient span, instead of carving the house down to make room. Carving a bay out of a bare 30x40 leaves a bunkhouse: a single bay sized around a 14x14 door, with the depth to actually park in it, eats most of the building.

30x40 Barndominium: common questions

6 questions we get asked most often about this footprint. If yours is not on the list, ask it directly.

Is 1,200 sq ft big enough to be a legal house in Georgia?
It depends entirely on the county and the zoning district, and the range across the counties we build in is wider than most people expect. Forsyth County requires 700 sq ft of heated floor area per dwelling unit in A1 and AG-Res. Cherokee County publishes no minimum for a site-built dwelling. Fannin County's land development ordinance sets a floor of 400 sq ft. At the other end, Coweta County requires 1,725 sq ft per unit in its Rural Conservation district, South Fulton requires 1,800 sq ft on the ground floor of a single-storey house in AG-1, and Walton and Jackson counties both require 1,400. Newton and Paulding go both ways depending on district: Newton allows 1,000 sq ft in A but demands 1,800 in RE and AR, and Paulding allows 1,100 in A-1 but demands 1,600 in R-1. The minimum floor area for your parcel is one of the first things we confirm.
Can I split a 30x40 into living space and a shop?
You can, but it is usually the wrong move, for two separate reasons. The first is arithmetic: at 1,200 sq ft total there is no spare length to give, so a shop bay comes out of the house rather than in addition to it. A single bay sized for a 14x14 door with real parking depth can take 900 sq ft, leaving roughly 300 sq ft to live in. The second reason is specific to Georgia. Where a county sets a minimum house size it measures heated floor area, and Jackson County's UDC § 105 states outright that heated floor area does not include garages or unheated basements. So an unconditioned shop bay contributes nothing toward the minimum. A 30x40 split 800 living and 400 shop reads to the county as an 800 sq ft dwelling, which fails minimums that the full 1,200 sq ft would have met. If the shop matters, the better answer is to add bays down the 40-foot axis, which is the cheap direction, or to build the shop as a separate structure.
Can I use a 30x40 as a guest house or in-law suite?
Sometimes 1,200 sq ft is too large rather than too small, which catches people out. Hall County regulates a detached suite as an accessory dwelling unit under Sec. 7.8.3: between 300 and 1,000 sq ft, site-built only, no more than two bedrooms, and it may not exceed the floor area of the principal dwelling. A 1,200 sq ft 30x40 is over the Hall cap. Athens-Clarke County allows one detached accessory unit only on a tract of at least ten acres, wholly within the rear yard, with a gross floor area of 50 percent or less of the principal residence's habitable area and fewer bedrooms than the principal residence — so a 1,200 sq ft guest building there needs a main house of at least 2,400 sq ft habitable. In Forsyth County an attached accessory apartment is permitted in A1 and AG-Res while a detached one is conditional. The rule that applies to your parcel decides the size before the layout does.
Will a stock 30x40 kit plan pass in Georgia?
Not without checking the county's appearance standards, and roof pitch is where stock packages fail most often. Bartow County requires a minimum 5:12 pitch under Sec. 10.1.4, and its own single-family permitting sheet tells applicants to confirm 5:12 at the zoning counter before applying. Walton County also requires 5:12, and its list of acceptable street-visible roof surfaces includes standing seam non-corrugated steel but not corrugated metal roofing; it prohibits vinyl and aluminium siding, requires 6 ft by 8 ft front and rear porches, and requires an enclosed two-car garage. Jackson County sets 3:12 under UDC § 3-050(d), limits street-facing roof surfaces to standing seam or other non-corrugated materials, and expressly permits non-corrugated metal siding. Many stock 30x40 packages are quoted at 1:12 or 2:12. Pitch is a frame input rather than a finish choice, so it has to be specified before the building is engineered, not changed afterward.
Can I build a small 30x40 now and add on later to reach the minimum?
In Bartow County, no — and it is written down. Sec. 10.1.2 requires a single-family dwelling to contain not less than 1,200 sq ft of heated living space and then adds that an existing structure may not include an addition to fulfil the minimum square footage. The area has to be there in the dwelling as built. That closes the shell-now-finish-later route as a way of meeting the number, which is exactly how people plan to get around a minimum. Building smaller now and adding on later is a reasonable strategy on its own terms in a county with a low minimum or none, but it cannot be the plan for satisfying a minimum floor area anywhere the county has written this kind of clause. Bartow also requires porches or landings of at least 5 ft by 5 ft on two sides.
Does a building this small still need an engineer?
Yes, and the footprint is not what decides it. Under the 2024 IRC with Georgia Amendments, R301.1.1 allows construction to the prescriptive provisions of the AWC Wood Frame Construction Manual, AISI S230 or ICC 400. A clear-span rigid frame or a post-frame building fits none of the three, so R301.1.3 applies and those elements have to be designed to accepted engineering practice. That is true of a 1,200 sq ft building exactly as it is true of a 4,000 sq ft one, because the frame type takes it off the prescriptive path, not the size. Georgia's counties say the same thing in their own words: Walton County's residential building packet states that stamped engineered plans are required for all barndominiums, and Carroll County has required a professional engineer letter of approval for inspections on barndominium homes since 1 August 2021. Georgia's Table R301.2 is filled in by the jurisdiction rather than the state, so the wind, seismic and frost criteria the engineering is run against are confirmed for your specific parcel.

Want this drawn for your program and your parcel? That is where a build actually starts.

Start your plans

Tell us what you want to build and we will draw a 30' x 40' building for your program, then confirm what it looks like on your parcel, the wind load it has to meet, and a realistic budget range. That conversation costs nothing.